Located near Aix-en-Provence, in France, PMB Alcen is a 130 employee SME. With a strong expertise in brazing, the company designs and manufactures complex mechanical assemblies and components (ceramic-metal, radio-frequency….), linear particle accelerators and cyclotrons. PMB is part of the industrial group ALCEN working in the fields of Defence & Security, Energy, Medical & Healthcare, Aeronautics & Space and large scientific instruments.
Features include:
- Integration of Digital Flat Panel (DDA) – Shielding and fixture bracketry.
- LINAC, object and DDA manipulators.
- Software suite – Monitoring, 3D reconstruction and volume visualization.
Applications for LINAC’s include:
- Aerospace (space flight components, aircraft structure, solid rocket fuel tanks).
- Defence (missiles, turbine blade, casting inspection).
- Research
- Industry (casting inspection, high-value metal detection).
Technical Details:
Model | Oriatron 3X | Oriatron 4X | Oriatron 6X | Oriatron 7X | Oriatron 9X |
Beam Energy (MeV) | 3 | 4 | 6 | 6.9 | 9 |
Dose rate (maximum at NFSS) (rad/min)
|
300 | 400 | 800 | 1200 | 3000 |
Nominal Focal Spot Size (NFSS) (mm)
|
1.7 | 1.7 | 1.7 | 1.7 | 2.0 |
Minimum Focal Spot Size (mm)
|
0.7 | 0.7 | 0.7 | 0.7 | N/A |
Flattener
|
Yes | Yes | Yes | Yes | Yes |
Beam Stability (rise time?) (s)
|
<5 | <5 | <5 | <5 | <5 |
Image quality (per ASTM E94)
|
OK | OK | OK | OK | OK |
Beam symmetry < +/- 5%
|
Yes | Yes | Yes | Yes | Yes |
Pulse Repetition Rate (Hz)
|
5 to 250 | 5 to 250 | 5 to 250 | 5 to 250 | 5 to 250 |
Primary Collimator Angle
|
32º Max – on customer request | 32º Max – on customer request | 32º Max – on customer request | 32º Max – on customer request | 32º Max – on customer request |
X-Y Collimator (4 independent jaws)
|
Feasible – Other models available – Motorized |
||||
HVL Steel (7.8 x 103 kg/m3
|
22mm | 25mm | 28mm | 29mm | 30mm |
Equivalent steel thickness
|
220mm | 250mm | 280mm | 310mm | 380mm |
Reduced Focal Spot:
As the PMB LINAC can be manufactured with a reduced focal spot down to 0.7mm, depending on the measurement method, this means the combination of LINAC and imaging system can produce greater image resolution, making it easier for the operator to detect even the smallest defects. As the reduced focal spot allows the object to be closer to the source, by the inverse square law, a higher dose rate can be achieved.